Plant Science Instruments / Porometers
PMR-5 Steady State PorometerThe PMR-5 is a hand-held unit using an gopen systemh measurement of leaf transpiration. There is an integral mass-flow controlled air supply and and manual control of humidity up to ambient. The lightweight cuvette is designed to couple the leaf to the ambient temperature using a fan, heat sink and radiation shield. There is a stirring fan in the chamber to minimize the boundary layer resistance. Digital humidity and temperature sensors accurate-ly monitor the air entering and leaving the cuvette. There are closely situated in the chamber with tortuous air paths to minimize the temperature difference between sensors. |
![]() |
AP4 Porometer
Stomatal aperture is the dominant factor in the diffusion conduc-tance of the leaf surfaces, which controls both the water loss From plant leaves and the uptake of CO2 for photosynthesis. |
![]() |
Plant Science Instruments / Water Potential Measurement
Dew Point Microvolmeter HR-33TThe standard in water potential measurement, Wescor`s Dew Point Microvoltmeter, model HR-33T, can determine Water potential using both dew point and we bulb methods.
|
![]() |
Plant Science Instruments / Oxygen Meter
FIBOX 3 Single Channel Fiber-Optic Oxygen Meter For Mini-SensorsThe Fibox 3 is a single channel, temperature compensated oxygen meter for use with fiberoptic oxygen minisensors based on a 2mm polymer optical fiber (POF). The smaller outer dimensions, low power consumption and a robust box make it ready forindoor and outdoor applications. For operation, a PC/Notebook with RS-232 interface is required. The Fibox is controlled using a comfortable software, which also saves and visualizes the measured values. The Fibox 3 has 2 analog outputs (0 - 5 V) and one trigger input (TTL) to be connected to a data logger. |
![]() |
Plant Science Instruments / Portable Photosynthesis System
CIRAS-2 Portable Photosynthesis and Chlorophyll Fluorescence Measurement SystemThe CIRAS-2 is a true differential system. It features 4 independent, non-dispersive Gas analyzers for accurate, simultaneous measurement of both CO2 and H2O Eliminating the problems associated with ggas switchingh systems. There are no moving parts. The analyzers (reference and analysis) include an infrared source, gold plated and highly polished sample cells and detectors. Theb analyzers act as absorption-meters measuring only in the 4.26 สm (CO2) and 2.60สm (H2O) wavebands ensuring accurate, rapid and stable results. |
![]() |
PLC6(U) Automatic Universal Leaf cuvetteFor measurement on broad leaves, some grasses and even needles. It features automatic control of temperature, Remote recording switch, twin PAR sensors at the leaf surface and an IR sensor fitted at the base for Accurate, non-contact leaf temperature measurement. Optional light units (quart halogen and LED) Are available for automatic control of light. |
![]() |